top of page

24-HOUR NATIONWIDE SUPPORT: (888)870-5935

  • X
  • Instagram
  • LinkedIn
  • Facebook
P1000591-1-scaled_edited.jpg

Selection of the appropriate sized  generator for your event is crucial for engineering the right solution for Peace of Mind.  Saunders’ fleet of paralleling generators has the most reliable track records in the live sports and live entertainment industries. All of our generators  are meticulously maintained and Saunders has installed redundant units for critical components.  We have one of the largest fleets of paralleling generators in the industry allowing our fleet to parallel to most other units regardless of size.  Our crew of generator tech/operators are well trained in operation, maintenance and trouble shooting. We operate nationwide. All our generators are CARB permitted for use in California and some units are DEP permitted for use in New York City.

Our fleet of towable generators range in size from 60KW to 600KW.  60KW  – 196KW generators can be towed by our fleet of Dodge Ram trucks; larger units are towed by our fleet of Peterbilt tractors.  Dodge and Peterbilt trucks are among the most reliable trucks in the trucking industry, ensuring timely delivery!

600KWs_at_Grammys_square.jpg
  • Rated at 70DB @ 50 ft
    Parallelable and AutoStart set up
    Exterior fueling and DEF
    900 Gallon diesel Fuel tank
    Consumption 42 gph at full load
    Towing Specs include 5th Wheel hitch and 5th Wheel air brake
    Weight: 34000 lbs (full fuel tank)
    Height 13’ Width 8’ Length 24’

    Distribution Panel Specs –
    5 per phase CamLok tails reverse N & G

    Voltage Settings
    120/208 3Ø
    277/480 3Ø

500KW-Gen-2_square.jpg
  • Rated at 65DB @ 50 ft
    Parallelable and AutoStart set up
    Exterior fueling via front mounted platform
    720 Gallon diesel Fuel tank
    Consumption 40 gph at full load
    Towing Specs include 5th Wheel hitch and 5th Wheel air brake
    Weight: 31,000 lbs (full fuel tank)
    Height 13’ Width 8’ Length 24’

    Distribution Panel Specs –
    4 per phase CamLok tails reverse N & G
    Bus Bar

    Voltage Settings
    120/208 3Ø
    277/480 3Ø
    120/240 3Ø (on some units)

2400A-Gen-3-1.jpg
  • Rated at 65DB @ 50 ft
    AutoStart set up & most parallelable
    Analog Control Panel
    Digital Volt, Amp, Hz and kW meters
    Exterior fueling into base tank
    300 Gallon diesel Fuel tank
    Consumption 20 gph at full load
    Towing Specs include military pintle hitch
    Electric or air brake
    7 way round plug trailer end
    Weight: 16,000 lbs (full fuel tank)
    Height 11’2” Width 7’ Length 18’4”

    Distribution Panel Specs –
    4-6 per phase CamLok tails reverse N & G depending upon unit
    Edison convenience outlets
    L2130 outlets
    Bus Bar

    Voltage Settings
    120/208 3Ø
    277/480 3Ø

300KW_Industrial_square.png
  • Rated at 85DB @ 50 ft
    AutoStart set up & parallelable
    Digital Control Panel & Meters
    Exterior fueling into base tank
    400 Gallon diesel Fuel tank
    Consumption 20 gph at full load
    Towing Specs include military pintle hitch
    Air brake
    7 way round plug trailer end
    Weight: 16,000 lbs (full fuel tank)
    Height 11’2” Width 7’ Length 18’4”

    Distribution Panel Specs –
    4 per phase CamLok tails reverse N & G
    Edison convenience outlets
    Bus Bar

    Voltage Settings
    120/208 3Ø
    277/480 3Ø
    120/240 1Ø

Bridgestone_Arena1.jpg
  • Rated at 70DB @ 50 ft
    Parallelable and AutoStart set up
    Fueling performed inside container
    450 Gallon diesel Fuel tank
    Consumption 40 gph at full load
    Towing Specs include 5th Wheel hitch and 5th Wheel air brake
    Weight: 34,000 lbs (full fuel tank)
    Two configurations available
    Height 13’ Width 8’ Length 24’
    Height 13’ Width 8’ Length 40’ (as shown in photo)
    With Stairs, add 4’ to width when parked.

    Distribution Panel Specs –
    4 per phase CamLok tails reverse N & G
    Bus Bar


    Voltage Settings
    120/208 3Ø
    277/480 3Ø

1600A-Gen-scaled-1.jpg
  • Rated at 60DB @ 50 ft
    AutoStart set up & most parallelable
    Two types of Control Panels
    Analog with Digital Volt, Amp, Hz and kW meters
    Full digital
    Exterior fueling into base tank
    150 Gallon diesel Fuel tank;
    Consumption 7gph 1000A
    8 gph 1400A
    14 gph 1600A at full loads
    Towing Specs include military pintle hitch
    Electric Brake
    7 way round plug trailer end
    Weight: 9500 lbs (full fuel tank) 9100 lbs for 1000A
    Height 9’5” Width 7.5’ Length 14’5”

    Distribution Panel Specs –
    3-4 per phase CamLok tails reverse N & G depending upon unit
    Edison convenience outlets
    L2130 outlets (1400A only)
    100A Bates (1600A & 1000Aonly)
    Bus Bar

    Voltage Settings
    120/208 3Ø
    277/480 3Ø
    120/240 1Ø (1600A & 1000A only) .

500A-Gen-scaled-1.png
  • Rated at 60DB @ 50 ft
    Analog Control Panels
    Exterior fueling into base tank
    90 Gallon diesel Fuel tank;
    Consumption 5 gph at full loads
    Towing Specs include military pintle hitch
    Electric Brake or Hydraulic surge
    7 way round plug trailer end
    Weight: 6000 lbs (full fuel tank)
    Height 7’ Width 7’ Length 14’

    Distribution Panel Specs –
    2 per phase CamLok tails reverse N & G
    Edison convenience outlets
    L2130 outlets
    Bus Bar

    Voltage Settings
    120/208 3Ø
    120/240 1Ø

600A_generator_square.png
  • Rated at 60DB @ 50 ft
    Analog Control Panels
    Exterior fueling into base tank
    100 Gallon diesel Fuel tank;
    Consumption 5 gph at full loads
    Towing Specs include military pintle hitch
    Electric Brake
    7 way round plug trailer end
    Weight: 6000 lbs (full fuel tank)
    Height 7’ Width 7’ Length 14’

    Distribution Panel Specs –
    2 per phase CamLok tails reverse N & G
    Edison convenience outlets
    L2130 outlets
    Bus Bar

    Voltage Settings
    120/208 3Ø
    120/240 1Ø

Hondas_Side_by_Side2_smaller.png
  • These small hand movable generators provide a 20A 120V circuit (Edison Style) for the EU3000 and a 50A 120V circuit (California Hubbell) / or 2 ea. 20A circuits 120V. For live events, we have the ability to parallel two EU3000s together for a 20A Edison redundant power circuit.

     

    Honda EU3000
    AC Output – 120V 3000W max.(25A) 2800W rated (23.3A)
    Receptacles – 20A 125V Duplex, 30A 125V Locking Plug
    DC Output – 12V, 144W (12A)
    Fuel Tank Capacity – 3.4 gal.
    Run Time per Tankful – 7.1 hrs. @ rated load, 20 hrs. @ 1/4 load
    Dimensions (L x W x H) – 25.9″ x 17.6″ x 22.0″
    Noise Level – 57 dB(A) @ rated load, 50 dB(A) @ 1/4 load
    Dry Weight – 131 lbs.

    Honda EU7000
    AC Output – 120/240V 7000W max. (58.3/29.1A) 5500W rated (45.8/22.9A)
    Receptacles – 20A 125V GFCI Duplex (2), 30A 125V Locking Plug, 30A 125/250V Locking Plug
    DC Output – N/A
    Fuel Tank Capacity – 5.1 gal.
    Run Time per Tankful – 6.5 hrs.@ rated load, 18.0 hrs. @ 1/4 load
    Dimensions (L x W x H) – 33.4″ x 27.6″ x 28.4″
    Noise Level – 58 dB(A) @ rated load, 52 dB(A) @ 1/4 load
    Dry Weight – 261 lbs.

DodgesLinedUp-scaled.jpg

Let us show you the Saunders difference...

bottom of page